2-7.
SITE SELECTION, SETUP, AND ASSEMBLY. (CONT)
(4)
(5)
(6)
(7)
Connect main power cable (3) to main power connection (2). Connect
other end of power cable to power source. Refer to TM 5-6115-585-12
for electrical connections on generator.
WARNING
Be sure that water pump cable (9, figure 2-11) does
not touch or cross water hoses, exhaust ducts, or fuel
lines. Melting/damage can occur causing leaking fuel
and water or electrical hazards.
Death by
electrocution, fire, or explosion could result.
NOTE
Lock power cables in place by rotating connector
clockwise.
Be sure water pump ON/OFF switch is in the OFF position.
Be sure water heater switch is in the OFF position.
Connect water pump cable (9) between water heater service outlet (7)
and water pump service outlet (8). Do not touch or cross water hoses,
exhaust ducts, or fuel lines.
2-40