TM 10--3510--221--24
0105 00--2
TYPICAL ANALOG INPUT SIGNAL FAULT -- Continued
0105 00
9. Check for correct signal (refer to WP 0010 00, Table 1) between suspect sensor test point on PCB1 (next to
J2) and PCB1 J1 terminal 3.
Is voltage in range specified in Table 1?
YES Go to step 11.
NO Go to step 10.
10. Replace suspect analog component and perform checkout.
Is fault corrected?
YES Return to normal operation.
NO Replace PCB1 (WP 0210 00).
11. Replace PCB11 and perform checkout (WP 0214 00).
Is fault corrected?
YES Return to normal operation.
NO Go to step 12.
12. Replace PCB9 and perform checkout (WP 0215 00).
Is fault corrected?
YES Return to normal operation.
NO Replace card cage (WP 0216 00).
END OF WORK PACKAGE