TM 10--3510--221--24
0111 00--6
LAUNDRY ADVANCED SYSTEM
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0111 00
TABLE 1. Unit PMCS -- Continued.
ITEM
NO.
INTERVAL
MAN--
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
4
Quarterly
Still Condenser
Fan
Inspect still condenser fan blade (13) for
damage. Replace fan blade if damage is
found (WP 0160 00).
Fan blade is
damaged.
5
Quarterly
Heater burner
blower
Clean and inspect burner blower (14).
a. Remove eight screws (15) then remove
cover (16) from blower shroud (17).
b. Remove any lint buildup on fan blades
(18) and inside of blower shroud (17).
c. Inspect insert (19) and halves of
coupling (20) for wear. Replace if
necessary (WP 0180 00).
d. Install cover (16) then secure with eight
screws (15).
Blower fan
blades are not
clean.
Coupling or
insert are
damaged.
The callouts on these illustrations match the callouts in the QUARTERLY PMCS for item numbers 4 and 5.
13
20
19
15
16
17
14