TM 10--3510--221--24
0111 00--14
LAUNDRY ADVANCED SYSTEM
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0111 00
TABLE 1. Unit PMCS -- Continued.
ITEM
NO.
INTERVAL
MAN--
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
11
Annually
Control System
Inspect welds on main control enclosure
(1), operator panels (2) and inverter
enclosure (3).
Cracks in welds
are present.
Inspect all enclosures for security. Ensure
doors (4) or panels (5) seal properly and
inside of enclosures show no evidence of
water.
Doors or panels
do not seal or
water is
entering
enclosure.
Inspect enclosures and conduit/cables (6)
for loose connections, rubbing wires, and
loose clamps.
Connections
are loose,
clamps are
loose, or wiring
is rubbing.
Inspect inlet duct (7) and outlet duct (8) for
security. Ensure each opens and closes
smoothly.
Ducts cannot
be opened and
closed.