TM 10--3510--221--24
0126 00--2
DOOR LOCK REPLACEMENT -- Continued
0126 00
10
9
1
3
4
2
1
7
11
5
6
8
INSTALLATION
1. Extend piston (7) on new door lock (2). Then thread locking pin (8) on to piston to previously recorded
dimension.
2. Install shim (6) onto door lock (2) then thread door lock into mounting block (5).
3. Install gaskets (4) onto connectors (3)
4. Thread connectors (3) into door lock (2).
5. Connect tubes (1) to door lock (2) as tagged.
6. Close drum door (9) and engage handle (10).
7. Use maintenance menu to pressurize air system (WP 0010 00).
8. Use maintenance menu to access control outputs function (WP 0010 00). Extend and retract door lock DN100
several cycles and verify:
a. Air connections do not leak
b. Locking pin (8) moves in and out of handle (10) without binding.
c. LED on position switch (11) is on when lock extended and is off when lock is retracted.
END OF WORK PACKAGE