TM 10--3510--221--24
0157 00--1
DOOR LOCK REPLACEMENT
0157 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Tape, Anti--Seizing (Item 10, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control enclosure
(WP 0112 00).
Air pressure must be vented (WP 0113 00).
REMOVAL
WARNING
Still piping can reach temperatures near 220o F when the water recycle system is
operating. Allow still piping to cool prior to performing maintenance. Always wear gloves
and eye protection. Failure to follow this precaution could result in severe burn injuries.
1. Drain and clean still (TM 10--3510--221--10).
2. Tag and disconnect tubes (1) from door lock (2).
3. Remove two screws (3), flat washers (4), and nuts (5), then remove door lock (2) from mounting angle (6).
4. Unthread pin (7) and nut (8) from door lock (2).
5. Remove two elbows (9) from door lock (2).
6. Clean anti--seizing tape from threads of elbows (9).