TM 10--3510--221--24
0166 00--2
EVAPORATIVE COOLER INLET VALVE
REPLACEMENT -- Continued
0166 00
2
1
6
8
14
13
15
18
10
11
5
9
7
3
4
12
17
16
19
INSTALLATION
1. Apply pipe thread sealant to threads nipple (16) and hex bushing (18).
2. Note direction arrow (19) on new solenoid valve (12) then thread hex bushing (18) into valve outlet.
3. Thread nipple (16) into inlet of solenoid valve (12).
4. Thread nipple (16) into tee fitting (17) with solenoid valve (12) oriented as shown.
5. Connect hose (14) to hose barb (15) then tighten clamp (13).
6. Connect electrical cable (11) to solenoid valve (12) then tighten screw (10).
7. Install filter cartridge (9) and cover (8) onto coalescer (4) then secure with clamp (7).
8. Connect tube (5) at fitting (6).
9. Perform a HEAT WATER operation with a water temperature setpoint of 90 degrees F (TM 10--3510--221--10).
Verify no water leaks exist.
10. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE