TM 10--3510--221--24
0184 00--2
FLAME DETECTOR REPLACEMENT -- Continued
0184 00
2
6
5
4
3
1
3
7
15
14
16
11
10
9
8
17
12
13
18
1. Insert lead wires (7) of new flame detector (15) through nipple (18) and pulling elbow (13) then thread nipple
into flame detector (15).
2. Insert lead wires (7) through conduit (17) and out of outlet body (11).
3. Insert lead wires (7) through outlet body (11) and into heater enclosure (3).
4. Position flame detector (15) on sight tube (16) then tighten captive nut (14).
5. Tighten conduit nut (12).
6. Install cover (9) and gasket (10) onto outlet body (11), then secure with two screws (8).
7. Connect leadwires (7) to sub--base (6).
8. Install flame programmer (5) onto sub--base (6) and secure with two captive screws (4).
9. Close door (2) and secure to heater enclosure (3) by tightening four latches (1).
10. Use maintenance menu to test heating system (WP 0010 00).
END OF WORK PACKAGE