TM 10--3510--221--24
0197 00--1/2 blank
FP300 RESET SWITCH REPLACEMENT
0197 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Loosen four latches (1), then open door (2) on heater enclosure (3).
2. Tag and disconnect wires from contact block (4).
3. Loosen captive screw (5) then remove contact block (4) from switch housing (6).
ROTATED 90_
6
5
4
1
2
3
INSTALLATION
1. Position new contact block onto switch housing (6) then tighten captive screw (5).
2. Connect wires to contact block (4) as tagged.
3. Close door (2) and secure to heater enclosure (3) by tightening four latches (1).
4. Use maintenance menu to test heating system (WP 0010 00).
END OF WORK PACKAGE