TM 10--3510--221--24
0199 00--1/2 blank
RELIEF VALVE REPLACEMENT
0199 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tape, Anti--Seizing (Item 10, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Disengage two latches (1), then open access door (2).
2. Open petcock (3), allow air to vent from air tank (4), then close petcock.
3. Unthread relief valve (5) from air tank (4) or manifold block (6).
ROTATED 90_
6
5
4
3
1
2
INSTALLATION
1. Apply anti--seizing tape to threads of new relief valve (5).
2. Thread relief valve (5) into tank (4) or manifold block (6).
3. Use maintenance menu to test air system (WP 0010 00). After air system is pressurized audibly check for air
leaks.
4. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE