TM 10-3510-222-24
2-40. INDICATOR LIGHT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Lamp Extractor (App B, Item 14)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
General Safety Instructions
WARNING
Voltage in this equipment is high enough to cause serious
injury or death. Do not replace light bulb with power on.
a.
REMOVAL
(1)
Unscrew shade lens (1) from indicator light (3).
(2)
Using lamp extractor, push lamp (2) in, twist counterclockwise and pull out.
b.
INSTALLATION
(1)
Install lamp (2) in indicator light (3).
(2)
Install shade lens (1).
Figure 2-29. Indicator Light
2-100