To replace a QD fitting, use a flathead screwdriver, loosen the water hose clamp (1) holding the damaged
QD coupling half (2) onto the hose (3).
Remove the damaged QD coupling half (2) from the hose (3).
Place a new or serviceable QD coupling half (2) onto the hose (3).
Place a new or serviceable water hose clamp into position over the end of the hose and the sleeve of the
coupling and using a flathead screwdriver, tighten the clamp (1).
REPLACE
Replace a freshwater or wastewater hose that leaks or is frayed and worn. Refer to work package 0065
00 for ordering data.
END OF WORK PACKAGE
1
2
3
2
1