NOTE
Prior to installation of a new pump, its power cord must be modified as
described in work package 0074, Figure 1.
Install the items removed in the previous step onto a new pump (1). Apply antiseize to copper joints being
reconnected. Clean PVC pipe ends with all-purpose cleaner and apply all-purpose cement when
reconnecting PVC pipe to pump. Place pump onto mounting plate (2), aligning the mounting bolts with
holes (3), and install selflocking nuts and flatwashers (4). Reconnect the feeder line with the ¾ union (5)
on top of the pump. Reconnect the drain line with the ¾union (6) to the front of the pump. To replace the
flexible hose joint (7) on the supply line (8), slide the hose clamps (9) over the ends of the PVC pipe.
Slide the flexible hose joint (7) onto the PVC pipe. Place hose clamps (9) over the ends of the joint and
tighten.
2
3
5
6
7
8
9
4
1
Install