TM 10-3510-223-13&P 0005 00
0005 00-35
After the freshwater system has been activated, check the water hose connections behind washers for
leaks. Hand-tighten any hose that leaks. If leak persists, notify unit maintenance. Close curbside doors.
The submersible wastewater pump empties wastewater from the internal wastewater tank. A float-on
switch turns on the pump when the water in the tank reaches a pre-set level. Similarly, another, float-off
switch shuts off the pump when the tank is empty. If the float-on level is exceeded, an alarm float switch
will set off the wastewater alarm. To operate the wastewater pump, push the PUMP RUN button.
Before placing the CSSL in operation, test the operation of each washer/dryer by briefly activating the
controls, and if the machine starts, resetting the controls.
After testing, operate washer/dryers as described in commercial manual and posted instructions.
To operate the space heater, adjust the heater control knob until the heater comes on. The heater should
not be operated while the washers and dryers are in operation.
To operate the exhaust fan, turn the VENTILATION FAN switch on the roadside raceway to ON.
To operate the 3,000 Gallon collapsible fabric tank(s) refer to TM 5-5430-227-12&P
Operate the TEMPER Section as described in TM 10-8340-224-13.
During operation of the CSSL, check exterior dryer exhaust vents daily for free air flow.
Refer to work package 0006 00 for precautions during operation under unusual conditions.
CAUTION
If the WASTEWATER ALARM goes off, push HORN SILENCE button on the
alarm box. Switch circuit breakers 10, 15, 16, 19, 23, and 28 of circuit
breaker panel #1 to OFF. Switch circuit breakers 15, 19, and 23 of circuit
breaker panel #2 to OFF. Discontinue use of CSSL and notify unit
maintenance.
HORN SILENCE
PUMP RUN
ALARM TEST
WASTEWATER ALARM
CONTROL PANEL
ALARM INSTRUCTIONS