TM 10-3510-226-23
0015 00
REPLACE-CONTINUED
Replace a Personnel Door Filter Assembly
1. Remove the screws (Figure 5, Item 7) retaining the filter assembly (Figure 5, Item 8) to the door and
remove the filter assembly.
2. Apply sealant to the replacement filter assembly flange (Figure 5, Item 8) and install the replacement
filter assembly. Retain with screws (Figure 5, Item 7).
3. Wipe excess sealant from replacement filter assembly (Figure 5, Item 8) flange.
7
8
Figure 5. Replace a Personnel Door Filter Assembly.
0015 00-5