11. Use a wrench to remove the screws retaining the pump casing (Figure 6, Item 17), and remove the
pump casing.
12. Remove the impellor (Figure 6, Item 20) by unscrewing the impellor from the shaft (Figure 6, Item
19).
13. Remove the seal face (Figure 6, Item 21) from the shaft (Figure 6, Item 19).
14. Remove the stationary seal face (Figure 6, Item 22) from the seal plate (Figure 6, Item 23).
15. Install the replacement stationary seal face (Figure 6, Item 22) into the seal plate (Figure 6, Item
23).
16. Install the replacement seal face (Figure 6, Item 21) onto the shaft (Figure 6, Item 19).
17. Install the impellor (Figure 6, Item 20).
18. Install the pump casing (Figure 6, Item 17) and retain with screws.
19
23
22
21
20
17
Figure 6. Replace the Pump Seal.
0036 00-11