TM 10-3510-226-23
0038 00
REPLACE-CONTINUED
12. Remove screws retaining junction box cover (Figure 9, Item 1) on replacement motor (Figure 9, Item
2) and remove junction box cover.
13. Install conduit (Figure 9, Item 8) onto replacement pump motor (Figure 9, Item 2) and retain with
locknut.
14. Connect wiring as tagged.
15. Install junction box cover (Figure 9, Item 1) and retain with screws.
16. Operate pump IAW procedures given in TM 10-3510-226-10, and monitor for normal operation.
17. Install guard panel.