TM 10-3510-226-23
0040 00
REPLACE-CONTINUED
Replace the Water Reuse Holding Tanks
WARNING
Ensure that all electrical power is shut off and disconnected before proceeding. The
circuit breaker box or individual circuit breaker should be locked and tagged out by
personnel following this procedure. Remember that the CBL is a wet environment.
Serious injury or death to personnel can result from electrocution if proper safety
precautions are not observed.
NOTE
Prior to tank removal for repairs, remove both washers IAW procedures given in WP
NOTE
To remove the Nano Tank, the WTS Hold Tank must be removed first.
1. Disconnect power to the CBL by disconnecting all power cables.
2. Drain tank (Figure 5, Item 4) completely.
3. Tag and remove all hose connections, electrical connections, and fittings from the damaged tank
(Figure 5, Item 4). Ensure that the level sensor and sight glass assembly is removed.
4. Remove the soap dispenser control modules (Figure 5, Item 5) from their mounts and place out of
the way.
5. Remove mounting hardware retaining the tank (Figure 5, Item 4) to the tank rack (Figure 5, Item 6).
6. Remove tank (Figure 5, Item 4).
7. Remove screws, washers, and nuts retaining top of tank (Figure 5, Item 4), and remove top.
8. Install the tank top and retain with fasteners.
9. Install the assembled tank (Figure 5, Item 4) in place and retain with original hardware.
10. Remount the soap dispenser control modules (Figure 5, Item 5).
11. Install hose connections, electrical connections, and fittings, including the level sensor and sight glass
assembly, onto the tank (Figure 5, Item 4) as tagged.
12. Monitor tanks for leakage.
0040 00-9