TM 10-4510-207-14
4.7. TOP FRAME ASSEMBLY REPAIR OR REPLACEMENT. CONTINUED
NOTE
Two different showerheads can be used on the manifold assembly.
Use the
following procedures as necessary for the showerheads installed.
(3) Remove two showerheads (8), washers (9), gaskets (10), and adapter (11).
(4) Remove two valves (12), nipples (13), and bushings (14).
(5) If alternate showerheads are being used, loose setscrews as necessary using hex wrench (15) then remove two
showerheads (16) and nipples (17).
(6) Remove cap (18) and couplings (19 and 20).
(7) Remove two nipples (21) and tees (22) from nipple (23).
d. Assembly.
(1) Be sure any defective, missing, or damaged components have been replaced.
(2) Apply sealing compound to threaded ends of nipple (23) and install two tees (22). Be sure both tee side fittings
are facing the same direction.
(3) Apply sealing compound to threaded ends of two nipples (21) then install nipples, and couplings (19 and 20 as
illustrated).
NOTE
Two different showerheads can be used on the manifold assembly.
Use the
following procedures as necessary for the showerheads installed.
(4) Apply sealing compound to threaded end of two bushing (14) and threaded ends of two nipples (13). Install
bushings, nipples, and two valves (12) as shown.
(5) Apply sealing compound to threaded end of two adapters (11) that mates with valve (12) then install two adapters,
gaskets (10), washers (9), and showerheads (8).
(6) If alternate shower heads are being used, apply sealing compound to threaded ends of two nipples (17) then install
two nipples and showerheads (16). Adjust showerheads as necessary and secure setscrews using hex wrench (15).
(7) Place showerhead manifold assembly in place and secure using two pipe brackets (7), four U-bolts (6), eight flat
washers (5), and new self-locking nuts (4).
(8) Install two hook and pile fastener strips (3) and secure using two flat washers (2) and screws (1).
e. Installation.
4-14