TM 10-7360-226-13&P
0006 00
CONTAINERIZED KITCHEN (WITH TRAILER)
OPERATION UNDER USUAL CONDITIONS
11. Locate the ends of the two clear plastic air conditioner condensation drain hoses. Position
them so the condensation drains outside of the mechanical room.
12. Retrieve the MBU fuel can adapter from its storage location to the left of the generator and
install it on a filled fuel can. Place this can between the two tie-down provisions in the floor on
the left side of the mechanical room. Strap the can down with one short rubber strap. Ensure
the vent valve on the fuel can adapter is open.
13. Connect the hose from the fuel can adapter to the fuel connection on the left wall, underneath
the Power Entrance Panel.
14. Place a second filled fuel can on the ground outside of the mechanical room.
15. Uncoil the generator's auxiliary fuel line from its storage location to the left of the generator and
connect it to the fuel can adapter.
NOTE
The normal method of fueling the generator is by a fuel can connected to
the auxiliary fuel line as described in the preceding steps. However, it can
also be manually refueled through an access door in the serving wing, to
the left of the Power Distribution Panel.
16. If the platform was installed outside the mechanical room in step 1, remove the platform and
the two wing jacks.
Platform Installation
If the CK is on the trailer, install the platform at the personnel door as follows:
1. Close the personnel door.
2. Hook the edge of the platform over the bracket under the door and rest the platform on the
trailer tongue.
3. Attach the two wing jacks to the platform.
4. Install the platform rail.
5. Install the stair/ladder and stair rail.
6. If desired, open the personnel door and hold it open using a short rubber strap.
Grounding
If the CK is to be energized from the onboard generator, the ground rod must be installed and the
ground cable connected as described below. If the CK is to be energized from external power, it
will be automatically grounded through the power source, and the following steps need not be
performed.
1. Remove the ground rod from its storage location next to the Power Entrance Panel inside the
mechanical room.
2. Using the slide hammer (WP 0049 00, Table 2, Item 29), drive the ground rod at least 8 feet
into the earth at a suitable location that is near enough for the grounding cable to reach from
the rod to the grounding terminal on the Power Entrance Panel (the cable is approximately 8
feet long).
3. Connect one end of the grounding cable to the ground rod using the clamp provided. Ensure
that the connection is tight.
Change 2
0006 00-14