TM 10-3510-209-10
Table 3-2. Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11. WASHER FAILS TO FILL WITH WATER. (Cont)
Step 5.
Check water float level.
Check float rod to see if it is sticking. If float rod is sticking and cannot be freed or is damaged,
notify your supervisor.
12. WASHER FILLS WITH WRONG AMOUNT OF WATER.
Step 1.
Inspect controller switches to determine whether switches are in the correct positions.
a.
Set switches on controller to compensate.
b.
If problem persists, proceed to next step 2.
Step 2.
Check to see if float level (2, FIG. 2-1) is sticking.
a.
Free the float operation.
b.
If water level problems persist, report problem to unit maintenance.
Step 3.
Check to see if hot and cold water valves operate. Valves should open and close when
switches on controller are activated.
a.
If valves do not operate properly, notify your supervisor.
b.
If valves operate properly, proceed to next step.
Step 4. Check air pressure gage on air tank for an indication of at least .70 psi (483 kPa).
a.
If pressure is below 70 psi (483 kPa), check circuit breaker on power distribution box for
the air compressor.
b.
If pressure is 70 psi (483 kPa), notify your supervisor.
13. WASHER FILLS WITH WRONG TEMPERATURE OF WATER.
Step 1.
Check for proper switch settings on controller.
a.
Set switches to proper setting.
b.
If temperature problem persists, proceed to next step.
3-10