TM 10-3510-209-24
Table 2-2. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
WATER HEATER PRESSURE GAGE INDICATES PULSATING PRESSURE. (Cont)
Step 4.
Check for plugged burner nozzle.
a.
If nozzle is plugged, replace burner nozzle. Refer to
paragraph 2-34.
b.
If nozzle is not plugged, proceed to next step.
Step 5.
Check for defective fuel pressure gage by substituting suspect gage
with a known good gage.
If gage is defective, replace fuel pressure gage. Refer to
paragraph 2-37.
7.
WATER HEATER FUEL PUMP LEAKS.
Step 1.
Check for loose strainer cover.
a.
If strainer cover is loose, tighten cover screws.
b.
If strainer cover is tight, proceed to next step.
Step 2.
Check for loose plugs.
a.
If plugs are loose, tighten plugs.
b.
If plugs are tight, proceed to next step.
Step 3.
Check for leaks in shaft seals.
a.
If shaft seals leak, repair or replace fuel pump. Refer to
paragraph 2-37.
b.
If seals are not leaking, proceed to next step.
Step 4.
Check for cracks in fuel pump.
a.
If fuel pump has cracks, replace fuel pump. Refer to
paragraph 2-37.
b.
If no cracks in fuel pump and problem persists, notify your
supervisor.
2-30