TM 10-3510-220-10
Table 3-2. Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
WATER PUMP FAILS TO DELIVER WATER. (Cont)
Step 3.
Check pump to verify that it has been adequately primed.
a.
If pump is not primed, refer to paragraph 2-8d and prime the
pump.
b.
If pump has been adequately primed, proceed to step 4.
Step 4.
Check water source to see if it is too shallow.
a.
If water source is too shallow, remove suction hose and place it
in deeper water. Refer to FM 10-280.
b.
If water source is not too shallow, proceed to step 5.
Step 5.
Check suction hose and strainer for clogs.
a.
If suction hose is clogged, remove and clean suction strainer.
b.
If suction hose is not clogged, proceed to step 6.
Step 6.
Check hose assemblies for air leaks.
a.
If air leaks are present, repair or replace hose assemblies.
Repair hose assembly by tightening hose clamps.
b.
If air leaks are not present and problem persists, notify your
supervisor.
Step 7.
Check manual reset thermal protector.
a.
Reset manual reset thermal protector on motor.
2.
WATER HEATER AND DRYER FAIL TO START
Step 1.
Check that electrical power is available to dryer and water heater.
a.
If no power is available, report problem to your supervisor.
b.
If power is available, proceed to next step.
3-3