TM 10--3510--221--24
0009 00--4
LAUNDRY ADVANCED SYSTEM CONTROLS AND INDICATORS -- Continued
0009 00
OPERATOR PANEL CONTROLS AND INDICATORS
Two operator panels are used on LADS. Operator panel A is used to operate washing/drying system A.
Maintenance personnel also use operator panel A to control, monitor and test LADS operation. Operator panel B is
used only to operate washing/drying system B. Figure 3 shows the location of the controls and indicators found on
the operator panels. Table 3 describes the use of these controls and indicators found on each operator panel.
6
7--10
5
4
3
2
1
Figure 3. Location of Operator Panel Control Enclosure Controls and Indicators.
Table 3. Operator Panel Controls and Indicators.
INDEX
DESCRIPTION
TYPE
FUNCTION
1
POWER
Indicator
Illuminates when power is applied to operator panel.
2
SYSTEM OPERABLE
Indicator
Illuminates green when system is ready to operate.
3
ATTENTION REQUIRED
Indicator
Illuminates red when system requires attention.
4
SILENCE ALARM
Pushbutton
Switch
Silences audible alarm.
5
ALARM
Audio
Sounds when a system attention or a fault occurs.
6
DISPLAY
Vacuum
Fluorescent
Shows system status and listing of menu options.
7--10
MENU SELECTION
Pushbutton
Switches
Used to select various menu options that appear on
display.