TM 10-3510-222-10
Table 2-1. Preventive Maintenance Checks and Services - continued.
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
10
Before
Dryer
cont.
c
Inspect electric controls for
Electric controls
loose or broken switches.
have loose or
broken switches.
d.
Inspect exhaust ac motor for
Exhaust ac
loose mounting hardware.
motor has loose
hardware.
e.
Inspect air duct hose for cuts,
Air duct hose has
rips, and hose out of round.
cuts and/or rips.
f
Inspect thermometer for broken
Thermometer
lens.
has broken lens.
g.
Inspect elbow (exhaust) for tight
Elbow fits
fit on dryer and position of
incorrectly.
elbow.
h.
Inspect metal hose (exhaust) is
Metal hose
properly installed on elbow.
improperly
installed on
elbow.
i.
Remove air duct hose.
j.
Remove lint from around
Lint builds up
thermometer, thermostatic
around probes.
switch and temperature control
probes.
k.
Install air duct hose.
2-20