TM 10-3510-222-10
2-9. OPERATING PROCEDURES.
WARNING
If EMERGENCY SHUTDOWN is required, on generator control panel turn MASTER SWITCH to
OFF. All electrical power to Laundry Unit will be cut off. Failure to observe this warning may
result in serious injury or death to personnel.
a.
Daily Start up.
WARNING
Ear protection is required when operating the Laundry Unit. Serious hearing loss could occur if
the Laundry Unit is operated without ear protection.
NOTE
If Laundry Unit was shutdown for a period of time, do steps below; if coming from initial
adjustment and checks, start with automatic washing or manual washing steps.
(1)
On generator, do starting procedures for generator. Refer to TM 5-6115-585-12.
(2)
On water pump, set toggle switch (3, figure 2-20) to ON.
(3)
On water heater, do substeps below.
NOTE
If water heater thermometer reading is above temperature control setting, temperature control
must be set to higher temperature.
(a)
Set water temperature control (1) to 160°F (71°C).
(b)
Open fuel shutoff globe valve (5, figure 2-21). Counterclockwise opens valve.
(c)
Set subcircuit breaker to ON.
(d)
If any questions on water heater, refer to TM 10-4520-259-13&P.
2-63