TM 10-3510-222-24
2-81. MODIFIED GENERATOR - continued.
(9) Remove two nuts (5) and bolts (10) from oil gage bracket (7) and generator (3) and remove oil gage bracket.
(10) Remove hose (6) from generator (3).
(11) Remove two nut; (8) from gage (9) and remove gage (9) from oil gage bracket (7).
(12) Mount gage (9) on generator bracket. Refer to TM 5-6115-585-12.
(13) Remove oil gage hose (6) from replacement generator.
(14) Remove three battery hooks (16) from replacement generator.
(15) Install three battery hooks (16) on generator (3) with washers and wing nuts.
b. REPAIR
Repair consists of replacing damaged or missing components of the modified generator.
(a) Exhaust hoses (17)
(b) Union (19)
(c) Pipe (18)
(d) Hose (6)
(e) Hooks (16)
(f)
Oil gage bracket (7)
c.
INSTALLATION
(1) Remove gage (9) from replacement generator mounting bracket. Refer to TM 5-6115-585-12.
(2) Using oil gage bracket (7) as a template, drill two 25/64th inch holes in generator per view A of Figure 2-71.
(3) Install gage (9) on oil gage bracket (7) with two nuts (8).
(4) Position oil gage bracket (7) on generator (3) and install two bolts (10) and nuts (5).
(5) Connect hose (6) to gage (9) and generator (3).
(6) Install union (19) and pipe (18) as one piece on generator (3).
(7) Position generator (3) (using forklift) on Laundry Unit.
(8) Install eight bolts (15), blocks (14), washers (13), lockwashers (12) and nuts (11) on generator (3) and
Laundry Unit.
(9) Install two generator exhaust hoses (17) on generator (3).
(10) Install three battery hooks (16) on generator (3).
(11) Install battery cover (Para 2-82).
2-185