CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 GENERAL INFORMATION
MAINTENANCE FORMS RECORDS AND REPORTS - TM-10-3510-224-13P_14LIST OF ABBREVIATIONS/ACRONYMS - TM-10-3510-224-13P_15EQUIPMENT DESCRIPTION AND DATA - TM-10-3510-224-13P_19LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (Internal) - TM-10-3510-224-13P_20Location of Major Components (Internal)DESCRIPTION OF SYSTEM COMPONENTSDESCRIPTION OF SYSTEM COMPONENTS FIG.COMMON TOOLS AND EQUIPMENT.EQUIPMENT DATA - TM-10-3510-224-13P_25REFERENCES.CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 THEORY OF OPERATION
CSSL and TEMPER FIG.Power Distribution System SchematicWashing and Drying System SchematicCSSL MINIMUM EMPLOYMENT CONDITIONS - TM-10-3510-224-13P_31Location of Controls and IndicatorsTable 1. Power Distribution Panel (Left Side) Controls and IndicatorsTable 2. Power Distribution (Right Side) Controls and IndicatorsTable 3. Interior Lights and Space Heater ControlsLABELS AND INSTRUCTION PLATES - TM-10-3510-224-13P_39Power Distribution Panels - TM-10-3510-224-13P_40Washer and DryerGFCI Receptacles.OPERATION UNDER USUAL CONDITIONS - TM-10-3510-224-13P_43UNPACKING AND INVENTORY OF CSSL COMPONENTS - TM-10-3510-224-13P_44UNPACKING AND INVENTORY OF CSSL COMPONENTS CONT.Table 1. CSSL ContentsCSSL Packing DiagramCSSL Packing Diagram FIG. - TM-10-3510-224-13P_48Prepare Power Distribution System for Use - TM-10-3510-224-13P_49Prepare Power Distribution System for Use CONT. - TM-10-3510-224-13P_50Set up Water System External Components - TM-10-3510-224-13P_51Set up Water System External Components FIG. - TM-10-3510-224-13P_52PREPARE WASHERS AND WATER SYSTEM FOR USEPREPARE DRYERS AND DRYING SYSTEM FOR USE - TM-10-3510-224-13P_54PREPARE TEMPER WITH ISO MODIFIED END SECTION FOR USEArch Assembly - TM-10-3510-224-13P_56Header Assembly - TM-10-3510-224-13P_57Purlin AssemblyPurlin Assembly CONT.Placement of Window Section - TM-10-3510-224-13P_60Placement of ISO Modified End SectionPlacement of End Section - TM-10-3510-224-13P_62Placement of End Section CONT.Becket Lacing Window and End Sections - TM-10-3510-224-13P_64Becket Lacing Window and End Sections CONT.Install Guy Line - TM-10-3510-224-13P_66Raising the Frame to Partially-Erect Position - TM-10-3510-224-13P_67Raising the Frame to Partially-Erect Position CONT. - TM-10-3510-224-13P_68Component Installation - TM-10-3510-224-13P_69Component Installation CONT. - TM-10-3510-224-13P_70Component Installation CONT. - TM-10-3510-224-13P_71Fully Erecting the Frame - TM-10-3510-224-13P_72Fully Erecting the Frame CONT. - TM-10-3510-224-13P_73Moving the TEMPER Section into Position - TM-10-3510-224-13P_74Moving the TEMPER Section into Position CONT.Complete Becket Lacing and TEMPER AttachmentStakes and Guy Lines - TM-10-3510-224-13P_77OPERATE CSSL - TM-10-3510-224-13P_78CSSL TEMPORARY SHUTDOWN - TM-10-3510-224-13P_79Using Municipal WaterPREPARE WASTEWATER COMPONENTS FOR SHIPMENT - TM-10-3510-224-13P_81PREPARE WASTEWATER COMPONENTS FOR SHIPMENT CONT. - TM-10-3510-224-13P_82PREPARE CSSL FOR RETURN SHIPMENT - TM-10-3510-224-13P_83PREPARE FRESHWATER COMPONENTS FOR SHIPMENT - TM-10-3510-224-13P_84Using a 3,000 Gallon freshwater tankPREPARE WASTEWATER COMPONENTS FOR SHIPMENT - TM-10-3510-224-13P_86PREPARE TEMPER WITH MODIFIED END SECTION FOR SHIPMENT - TM-10-3510-224-13P_87PREPARE TEMPER WITH MODIFIED END SECTION FOR SHIPMENT CONT. - TM-10-3510-224-13P_88PREPARE TEMPER WITH MODIFIED END SECTION FOR SHIPMENT CONT. - TM-10-3510-224-13P_89Lowering the Frame - TM-10-3510-224-13P_90Removing the Fabric - TM-10-3510-224-13P_91Frame Disassembly - TM-10-3510-224-13P_92PREPARE POWER DISTRIBUTION SYSTEM FOR SHIPMENT - TM-10-3510-224-13P_93PACKING CSSL FOR RETURN SHIPMENT - TM-10-3510-224-13P_94PACKING CSSL FOR RETURN SHIPMENT TABLECSSL Packing Plan FIG.OPERATION UNDER UNUSUAL ENVIRONMENT/WEATHER CONDITIONSUsing a 3,000 Gallon Freshwater Tank:Using a 3,000 Gallon Wastewater Collection TankOperation in snowy or muddy conditions - TM-10-3510-224-13P_100LUBRICATION REQUIREMENTS - TM-10-3510-224-13P_103CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 OPERATOR TROUBLESHOOTING PROCEDURES
Procedure 1: Loss of PowerProcedure 2: Water LeakIntroduction, PMCS ProceduresLubrication Service IntervalsTable 1. Preventive Maintenance Checks and Services for the CSSLTable 1. Preventive Maintenance Checks and Services for the CSSL-Continued - TM-10-3510-224-13P_114Table 1. Preventive Maintenance Checks and Services for the CSSL-Continued - TM-10-3510-224-13P_115Table 1. Preventive Maintenance Checks and Services for the CSSL-Continued - TM-10-3510-224-13P_116Table 1. Preventive Maintenance Checks and Services for the CSSL-Continued - TM-10-3510-224-13P_117Table 1. Preventive Maintenance Checks and Services for the CSSL-Continued - TM-10-3510-224-13P_118Table 1. Preventive Maintenance Checks and Services for the CSSL-Continued - TM-10-3510-224-13P_119OPERATOR MAINTENANCE CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 INSPECT, SERVICE
OPERATOR MAINTENANCE CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 INSPECT, SERVICE CONT.
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 SERVICE UPON RECEIPT
Inspection - TM-10-3510-224-13P_126CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 351-01-485-0457 UNIT TROUBLESHOOTING PROCEDURESP rocedure 1: Loss of PowerProcedure 2: Water LeaksProcedure 3: No Water PressureUNIT MAINTENANCE CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 POWER ENTRY CONNECTORS
UNIT MAINTENANCE CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 POWER DISTRIBUTION PANEL INSPECT
UNIT MAINTENANCE CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 POWER DISTRIBUTION PANEL INSPECT FIG.
FLUORESCENT LIGHTS INSPECT, REPAIR FLUORESCENT LIGHTS INSPECT, REPAIR FIG.INTERIOR SWITCHES AND RECEPTACLES INSPECT, REPLACEINTERIOR SWITCHES AND RECEPTACLES INSPECT, REPLACE CONT. - TM-10-3510-224-13P_138INTERIOR SWITCHES AND RECEPTACLES INSPECT, REPLACE CONT. - TM-10-3510-224-13P_139INTERIOR SWITCHES AND RECEPTACLES INSPECT, REPLACE CONT. - TM-10-3510-224-13P_140INTERIOR SWITCHES AND RECEPTACLES INSPECT, REPLACE FIG.FRESHWATER PUMP AND INTERNAL FRESHWATER LINE INSPECT, SERVICEFRESHWATER PUMP AND INTERNAL FRESHWATER LINE INSPECT, SERVICE FIG.PRESSURE TANK INSPECTPRESSURE SWITCH/GAUGE INSPECTSUMP PUMP AND FLOAT SWITCH INSPECTWASTEWATER PVC PIPES INSPECTWASHER AND DRYER INSPECTVENT FAN INSPECTSPACE HEATER INSPECTWATER HOSES INSPECT, REPAIR, REPLACEQuick Disconnect (QD) FittingQuick Disconnect (QD) Fitting FIG.CSSL MODIFIED END SECTION INSPECT, REPLACEROOFGRIP INSPECT, REPLACEDIRECT SUPPORT TROUBLESHOOTING PROCEDURESProcedure 1: System Power LossProcedure 2: Internal Component Power LossProcedure 3: External Component Power LossMODIFIED FOLDING STEP INSPECT, REPLACEPOWER ENTRY CONNECTORS TESTPOWER ENTRY CONNECTORS TEST CONT.POWER DISTRIBUTION PANEL TEST, REPLACEMain BreakerMain Breaker FIG. - TM-10-3510-224-13P_179Main Breaker FIG. - TM-10-3510-224-13P_180Main Breaker FIG. - TM-10-3510-224-13P_181LUORESCENT LIGHTS TEST, REPLACELUORESCENT LIGHTS TEST, REPLACE FIG.FRESHWATER PUMP AND INTERNAL FRESHWATER LINE REPLACE FRESHWATER PUMP AND INTERNAL FRESHWATER LINE REPLACE FIG. - TM-10-3510-224-13P_186FRESHWATER PUMP AND INTERNAL FRESHWATER LINE REPLACE FIG. - TM-10-3510-224-13P_187PRESSURE TANK REPLACEPRESSURE TANK REPLACE FIG.PRESSURE SWITCH AND GAUGE REPLACEPRESSURE SWITCH AND GAUGE REPLACE FIG.SUMP PUMP AND FLOAT SWITCH REPAIR, REPLACESUMP PUMP AND FLOAT SWITCH REPAIR, REPLACE FIG. - TM-10-3510-224-13P_194SUMP PUMP AND FLOAT SWITCH REPAIR, REPLACE CONT.SUMP PUMP AND FLOAT SWITCH REPAIR, REPLACE FIG. - TM-10-3510-224-13P_196WASTEWATER PVC PIPES REPAIRWASTEWATER PVC PIPES REPAIR FIG.WASHER/DRYER REPAIR, REPLACEWasher Drive BeltWasher RemovalDryer RemovalWasher Replace - TM-10-3510-224-13P_203Washer Replace FIG.VENT FAN TEST, REPAIR, REPLACEVENT FAN TEST, REPAIR, REPLACE CONT.VENT FAN TEST, REPAIR, REPLACE FIG.SPACE HEATER TEST, SERVICE, REPLACESPACE HEATER TEST, SERVICE, REPLACE CONT. - TM-10-3510-224-13P_210SPACE HEATER TEST, SERVICE, REPLACE CONT. - TM-10-3510-224-13P_211CONTAINERIZED SELF SERVICE LAUNDRY NSN 3510-01-485-0457 REFERENCES
Technical Manuals-ContinuedCONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 THE ARMY MAINTENANCE SYSTEM MAC
Explanation of Columns in the MAC - TM-10-3510-224-13P_218Explanation of Columns in the Tools and Test Equipment Requirements - TM-10-3510-224-13P_219Table -1. MAC for Containerized Self Service Laundry (CSSL) - TM-10-3510-224-13P_220Table-1. MAC for Containerized Self Service Laundry (CSSL)-Continued - TM-10-3510-224-13P_221Table-1. MAC for Containerized Self Service Laundry (CSSL)-Continued - TM-10-3510-224-13P_222Table-3. Remarks for Containerized Self Service LaundryINTRODUCTION TO REPAIR PARTS AND SPECIAL TOOLS LISTSource Code - TM-10-3510-224-13P_226Maintenance Code - TM-10-3510-224-13P_227NATIONAL STOCK NUMBER (NSN) (Column (3)).EXPLANATION OF CROSS REFERENCE INDEX FORMAT AND COLUMNS - TM-10-3510-224-13P_229Fig ColumnHow To Locate Repair Parts - TM-10-3510-224-13P_231Figure 1. Group 01 Cargo ContainerGROUP 01 CARGO CONTAINER REPAIR PARTS AND SPECIAL TOOLS LIST GROUP 0101 MODIFIED FOLDING STEP REPAIR PARTS AND SPECIAL TOOLS LISTGROUP 0101 MODIFIED FOLDING STEP REPAIR PARTS AND SPECIAL TOOLS LIST CONT.Figure 3. Group 0201 Power Entry ConnectorsGROUP 0201 POWER ENTRY CONNECTORSFigure 4. Group 0202 Power Distribution PanelGROUP 02 ELECTRICAL SYSTEMFigure 5. Group 0203 Fluorescent LightsGROUP 0203 FLUORESCENT LIGHTSFigure 6. Group 0204 Interior Switches and Receptacles.GROUP 0204 INTERIOR SWITCHES AND RECEPTACLES - TM-10-3510-224-13P_255Figure 7. Group 0205 Exterior Power Cables.GROUP 0205 EXTERIOR POWER CABLESFigure 8. Group 0301 Freshwater Pump and Internal Freshwater LineFigure 8. Group 0301 Freshwater Pump and Internal Freshwater Line. (Sheet 2 of 2)GROUP 0301 FRESHWATER PUMP AND INTERNAL FRESHWATER LINEGROUP 0301 FRESHWATER PUMP AND INTERNAL FRESHWATER LINE CONT.Figure 9. Group 0302 Pressure TankGROUP 0302 PRESSURE TANK Figure 10. Group 0303 Pressure Switch and GaugeGROUP 0303 PRESSURE SWITCH AND GAGEFigure 11. Group 0401 Sump PumpGROUP 0401 SUMP PUMPFigure 12. Group 0402 Float SwitchGROUP 0402 FLOAT SWITCHFigure 13. Group 0403 Wastewater PVC PipesGROUP 0403 WASTEWATER PVC PIPESFigure 14. Group 05 Washer/DryerGROUP 05 WASHER/DRYERFigure 15. Group 06 Vent FanGROUP 06 VENT FAN ASSEMBLY Figure 16. Group 07 TEMPER SectionsGROUP 07 TEMPERFigure 17. Group 08 Space HeaterGROUP 08 SPACE HEATER Figure 18. Group 09 3,000 Gallon TankGROUP 09 3,000 GALLON TANK Figure 19. Group 10 Water HosesGROUP 10 WATER HOSESFigure 20. Group 11 CSSL Modified End SectionGROUP 11 TEMPER MODIFIED END SECTIONGROUP 11 BULK MATERIALCONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 NATIONAL STOCK NUMBER INDEX
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 SPECIAL TOOLS LIST
PART NUMBER INDEX - TM-10-3510-224-13P_319PART NUMBER INDEX CONT. - TM-10-3510-224-13P_320PART NUMBER INDEX CONT. - TM-10-3510-224-13P_321CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS LISTComponents of End ItemTable-1. Components of End Item ListTable-2. Basic Issue Items ListCONTAINERIZED SELF SERVICE LAUNDRY (CSSL) ADDITIONAL AUTHORIZATION LIST (AAL)CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) EXPENDABLE AND DURABLE ITEMS LISTTable 1. Expendable and Durable Items List-ContinuedCONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MANDATORY REPLACEMENT PARTS LISTCONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 ILLUSTRATED LIST OF MANUFACTURED ITEMS
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 ILLUSTRATED LIST OF MANUFACTURED ITEMS CONT.
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) NSN 3510-01-485-0457 ILLUSTRATED LIST OF MANUFACTURED ITEMS FIG.
Heater ModificationHeater Modification FIG.Abbreviations and AcronymsHow to Locate Repair Parts Packing CSSL for Return Shipment - TM-10-3510-224-13P_341The Metric System and Equivalents - TM-10-3510-224-13P_355