TM 10-3510-224-13&P
0002 00
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (Internal).
Container. Modified general cargo container (1) with forklift pockets (2) and ISO fittings (3) for moving and lifting the
container. Double doors are located at each end of the container. The personnel door (4) serves as main access door
to the CSSL, and the rear door (5) provides access to the utility wall containing a freshwater panel (6), wastewater
panel (7), power entry box (8) and vent fan (9). Located inside the container is a freshwater pump (10), wastewater
tank (11) and pressure tank (12). An additional double service door (13) on the container side allows access to the rear
of the washer/dryers (14). Built-in, hinged steps (15) and a handgrip (16) allow access to the top of the container
Space Heater. Installed inside the container at the rear, the heater (17) provides interior heating of the container
when the CSSL is not in operation.
Power Entry Panel. The Power Entry Panel (8) is located in the utility wall and includes two 208 VAC, 3 Phase input
connectors (18) for power supply to both circuit breaker panels right (19) and left (20), a 110 VAC GFCI utility
receptacle (21) used for TEMPER interior lights, a 30 AMP twist lock receptacle (22) and a 60 AMP Class L connector
(23). A ground terminal (24) is located in the lower right corner of the panel.
Power Distribution Panel (Right Side) (19). This panel contains a main breaker, and powers washers/dryers (14) #1
(a), 3 (c) and 5 (e) CSSL interior lights (25), the 60 AMP Class L connector (23), the space heater (17), the sump
pump (26), the fresh water pump (10) and the vent fan (9).
Power Distribution Panel (Left Side) (20) This panel contains a main breaker, and powers washer/dryers (14) # 2,
(b) 4, (d) and 6 (f), as well as the 30 AMP twist lock receptacle (22) and the 110 VAC GFCI utility receptacle (21).
Freshwater and Wastewater Panels. The utility wall freshwater supply (6) and wastewater drain panel (7) hose
connections facilitate the following connections:
Outside CSSL: Fresh water connection and wastewater connection to external source and disposal point,
respectively.
Inside CSSL: Fresh water connection to the fresh water pump, and wastewater connection from the
wastewater holding tank.
CSSL Interior lights and light Switch. Two fluorescent light fixtures (25) are controlled from the light switch (27)
located on the side wall near the personnel door.
Washers/Dryers #1 thru #6 (a thru f). The washer/dryers are mounted to the container floor and wall. The power
cord of each washer/dryer unit is plugged into a twist-lock receptacle (28) located on the overhead raceway. One fresh
water hose (29) connects each washer to the ¾ fresh water supply line (30). Using a standard Y connector. The
washer drain hoses (31) are connected to the 3 PVC drain (32).
Freshwater Pump. The freshwater pump (10) is mounted onto the container floor and is connected to the fresh water
supply panel. It provides fresh water under pressure to the main supply line when a 3,000 Gallon storage tank is used.
Wastewater Tank and Sump Pump. The wastewater tank (11) collects wastewater generated by the
washers through the 3 PVC drainpipe (32). A sump pump (26) evacuates the wastewater from the tank to the
designated external collection point or disposal site.
0002 00-2