TM 10-3510-226-23
0025 00
TEST-CONTINUED
Test the Emergency Stop
WARNING
This equipment operates at high voltages. Use extreme caution, observe all warnings,
and follow all safety procedures. Failure to observe safety precautions may result in
injury or death to personnel.
1. Disconnect power at the main circuit breaker and open PLC enclosure.
2. Tag and disconnect wiring from the two switch terminals (Figure 25, Item 51).
3. Use an ohmmeter to test for continuity across the two switch terminals (Figure 25, Item 51).
4. Connect wiring to the two switch terminals (Figure 25, Item 51) as tagged.
5. Close PLC enclosure and monitor for normal operation.
51
Figure 25. Test the Emergency Stop.
0025 00-31