CAUTION
Do not over tighten the pressure switch tubing compression nut. Over tightening the pressure
switch will strip it. Failure to comply may result in damage to component.
19. Install the pressure switch tubing (Figure 7, Item 16) onto the pump casing (Figure 7, Item 17) and
retain with compression nut.
20. Install the drain hose (Figure 7, Item 14) onto the pump casing (Figure 7, Item 17) and retain with
hose clamp.
21. Install the pump suction hose (Figure 7, Item 15) onto the hose barb and retain with hose clamp.
22. Install the pressure relief valve hose (Figure 7, Item 5) and retain with hose clamp.
23. Install the discharge hose (Figure 7, Item 13) and retain with hose clamp.
24. Install heat trace, and recover pump with insulation.
25. Close pump drain valve (Figure 7, Item 24). Operate IAW procedures given in TM 10-3510-226-10
and monitor for normal operation.