15. Seat the pump adapter (Figure 4, Item 7) to the pump casing (Figure 4, Item 8) and retain in place
with bolts.
16. Install the dust cap (Figure 3, Item 9) onto the motor.
17. Secure the pump motor (Figure 4, Item 2) to the pump mount (Figure 4, Item 6) with bolts, washers,
and nuts.
18. Remove screws retaining end cover (Figure 4, Item 1) on replacement pump motor (Figure 4, Item
2), and remove end cover.
19. Knock out conduit plug if necessary.
20. Install conduit (Figure 4, Item 14) to motor, and retain with locknut.
21. Connect conduit wiring to motor leads as tagged.
22. Install pump end cover (Figure 4, Item 1), and retain with screws.
23. Operate pump IAW procedures given in TM 10-3510-226-10, and monitor for normal operation.
0037 00-8