TM 10-3510-226-23
0050 00
REPLACE
Replace the Washer Emergency Stop Switch
WARNING
Ensure that all electrical power is shut off and disconnected before proceeding. The
Circuit Breaker box should be locked by personnel following this procedure. Serious
injury or death can result from electrocution if proper safety precautions are not observed.
1. Switch the washer circuit breaker to OFF.
2. Unlock and open control panel (Figure 2, Item 1).
3. Tag and disconnect wiring from switch (Figure 2, Item 2).
4. Loosen the screw (Figure 2, Item 3) securing the retaining catch (Figure 3, Item 4).
5. Use a screwdriver to lift the retaining catch (Figure 3, Item 4) on the switch (Figure 3, Item 2),
separate the switch halves, and remove the switch.
NOTE
The switch halves are marked for alignment to ease reassembly.
NOTE
When installed, the switch may be free to rotate within the limits imposed by the wiring.
6. Install the halves of the replacement switch (Figure 3, Item 2), into the control panel (Figure 2, Item
1), and lock halves together.
7. Tighten the screw (Figure 2, Item 3) securing the retaining catch (Figure 3, Item 4).
8. Reconnect wiring as tagged.
9. Close and lock control panel (Figure 2, Item 1).
10. Reconnect power and monitor for normal operation.
0050 00-3