TM 10-3510-226-23
0064 00
TEST-CONTINUED
6. Disconnect wiring from switch (Figure 2, Item 6).
7. Depress switch (Figure 2, Item 6) to open circuit, and use an ohmmeter to test for infinite resistance.
9. Replace a switch (Figure 2, Item 6) that fails either test.
10. Reconnect wiring as tagged.
11. Install dryer front (Figure 1, Item 5), and retain with screws
12. Close control panel (Figure 1, Item 3)
13. Install door (Figure 1, Item 4) and retain with screws.
14. Install top front panel (Figure 1, Item 1) and lint compartment panel (Figure 1, Item 2).
15. Connect power, operate IAW procedures given in TM 10-3510-226-10, and monitor for normal
operation.
6
Test here
Figure 2. Test the Dryer Emergency Stop Switch.
0064 00-3