TM 10-4510-208-13&P
0023 00
Inspect Power Service Panel Components
WARNING
Use caution when inspecting power service panel components. Remember that the
shower is a wet environment, inside and out. Touching a live wire can cause serious
injury or death to personnel.
1. Inspect the power service panel (1) for material damage and corrosion.
2. Inspect the convenience outlets connection (2) for material damage or corrosion (Containerized
Shower only).
3. Inspect 60A power input connection (3) for evidence of material damage, loose hardware, corrosion,
dirt, or missing cap (Containerized Shower only).
4. Inspect the 20A 120/208V 3 phase connection (4) for evidence of material damage, loose hardware,
corrosion, dirt, or missing cap (Containerized Shower only).
5. Inspect the 20A 120V connection (5) for evidence of material damage, loose hardware, corrosion,
dirt, or missing cap.
6. Inspect the twistlock connectors (6) on the power cables (7) for material damage, such as dents,
cracks.
7. Visually inspect the power cables (7) for material damage such as ripped insulation, exposed wires,
or burned or melted components.
0023 00-7