TM 10-4510-209-13&P
0016 00
Table 1. Preventive Maintenance Checks and Services for Containerized Latrine (CL) &
Containerized Latrine System (CLS) Continued.
Item No.
Interval
Item To Be
Procedure
Equipment
Checked Or
Not Ready/
Serviced
Available If:
Inspect cables (1) for visible damage. Frayed or otherwise
Electrical
damaged power supply
2
Before/During/
cable. Improper
After
Check for frayed insulation, loose
connections, or cables lying in water. connections on power
service panel.
Ensure that grounding rod (2) is
Power entry panel or
connected to the power entry panel
circuit breaker panel
(3) and it is firmly inserted into the
damaged.
ground.
Switches damaged or
Check power entry panel (3) and
Interior fluorescent light
Check circuit breaker panel (5) and
fixtures have broken or
switches (6) for physical damage.
Check water supply pump switch (7) missing safety covers,
burnt or darkened
for physical damage.
fluorescent tubes,
Check electrical internal/external
loose or missing
outlets for physical damage.
Check fluorescent light fixtures (8) for conduit and frayed or
exposed wires.
broken or missing safety
Container not properly
covers (9), burnt or darkened
grounded.
fluorescent tubes (10), missing
retaining clips (11), loose or missing
conduit and frayed or exposed wires.
Outlet test button does
Monthly
GFCI Outlets
Press TEST button on GFCI outlets,
not "pop".
and reset if outlet test button "pops".
0016 00-3