TM 10-4510-209-13&P
0057 00
REPLACE
Replace Brass Fittings
NOTE
1. Ensure water heater and water pump circuit breakers are set to the OFF position.
2. Release pressure from the system by opening the urinal flush valve.
3. Use a pipe wrench or slip joint pliers to prevent attached brass plumbing from turning.
4. Use a pipe wrench to unscrew brass fitting (1) from attached plumbing.
5. Coat the threads of the replacement fitting (1) with pipe sealant or antisieze tape.
6. Screw the replacement fitting (1) into position. Ensure it is tight.
Replace Flex Hose
1. Ensure water heater and water pump circuit breakers are set to the OFF position.
2. Release pressure from the system by opening the urinal flush valve.
3. Use a screw drive to loosen the screw on the hose clamp (2) and loosen the clamp from the flex hose
(3).
4. Remove damaged hose (3) from pipe nipple.
5. Cut replacement hose to appropriate length.
6. Remove hose clamp (2) from damaged hose and place on replacement hose.
7. Attach replacement hose on pipe nipple and secure to nipple with hose clamp. Tighten hose clamp.
1
3
2
0057 00-16