TM 9-4940-444-14 & P
MAINTENANCE BULLETIN
V-288
GG100B, GG200B AND
GL200B SERIES VALVES
MOUNTING:
Item
Part
No.
Qty.
Description
No.
These 4-way, 2 position " ported valves will operate
1
1
Spool Return Spring
mounted in any position. Models GG100B and GG200B
2
1
Spool
have tapped side ports, ONLY. They may be in-line
3
1
Up Seal
mounted and supported by the connecting piping. Or,
4
1
Gasket, End Cover
they may be bolted down to any reasonably flat surface
5
2
Mtg. Screws, End Cover
by means of two (2) 3/32" diameter mounting holes
(Not Shown)
provided. Models GG1028 and GG202 are furnished
6
1
Combo-Gasket, Body
P46184
with the tapped side ports plugged and the valve body
P20074-0100
10
2
Mtg.
Screws,
Conduit
drilled through to provide o-ring gasketed, bottom
Adapter To Body (Not
porting. Any combination of tapped side and gasketed
Shown)
11
1
Gasket, Solenoid Cover
bottom ports may be used.
15
1
Solenoid Cover Assy
PL3387
Supply line to the Inlet port must be adequate to maintain
19
1
Compression Gasket
a minimum of 35 PSI in the IN port chamber at all times.
20*
1
Top Seat Assy
If several valves are being operated from a common
27
1
0 Ring, Coil
supply line, this line must be adequately sized to handle
28
1
Plunger Spring
the total air flow requirement.
29*
1
Plunger
Electrical CAUTION: Coils should be operated within
30**
1
Solenoid Coil
See coil spec.
+10/-15% of their nominal rated voltage (7.7 watts, 0.24
list
49
1
Spring Guide Pin
amps inrush, 0.12 amps holding on 120 volt/60 cycle).
50
1
Plug-In Receptacle/Leads
P75029
Check voltage rating on each valve body before electrical
51
1
Side Port Body Assy O
PS5391
hookup.
Check coil specification list for optional
PS5392
52
1
Side & Bottom Port Assy.
voltages.
"2" (Includes 4 pipe
AIR LEAKAGE THROUGH VALVE EXH PORT: First be
plugs, 4 o-ring seals)
sure leak is in the valve and not across the piston of the
55
2
Screws, Pilot Head Plate
P200380040
cylinder being operated by the valve. This may be
(GG100B) (Not Shown)
checked by disconnecting first one, then the other of the
56
1
Rubber Ball (GG00100B)
P20041-0012
58
1
Solenoid Cover & Lens
PL3692
cylinder lines. If leakage is isolated to the valve, Install
Assy (GL2008)
spool service kit PS5386 and/or solenoid service kit
PL98382
61**
1
PS5387.
Lamp (GL200B Specify
NOTE: Seals on the spool assembly are NOT
Voltage)
replaceable. If they are worn or damaged, replace
the complete spool assembly (PS5388). Also check
condition of molded seats in both ends of solenoid
NOTE:
Body assy. PS5391 or PS5392 permit easy
plunger and their mating orifices in the conduit
conversion of original "A" Series GG
adapter and top seat assemblies; order PS5387 for
Valves to current "B" Series GG Valves.
replacements.
*Item No. 20 and 29 are related wear parts. Both parts
should be replaced when servicing valve. Order solenoid
SOLENOID COIL IDENTIFICATION AND
service kit PS5387.
SPECIFICATION LIST
**If solenoid coil voltage is not specified, 120 Vac, 60 Hz
will be furnished.
PART NO.
60HZAC
50HZAC
DC
P4615401
120V
110V
30V
P4615402
240V
220V
60V
P4615403
480V
440V
120V
P4615404
24V
22V
6V
P4615421
48V
44V
12V
P4615422
96V
88V
24V
69