Section V. MAINTENANCE OF MISCELLANEOUS ITEMS
This section describes the organizational maintenance instructions for the miscellaneous items listed in group 01 for the
bath unit. These items include the bath unit baseboard and straps; and the shower stand head, guard, riser, flow control
valve, reducing couplings,' and pipe nipples. Unless otherwise specified, the following instructions in this section apply
generally to the items used for all five Army models SPE 35, SPE 35A, SPE 41, SPE 44, SPE 45 and York-Shipley
Model YS49279. Any differences will be so specified in the applicable paragraphs, by the particular Army model number.
The organizational maintenance instructions for the generator sets are given in the applicable technical manuals listed in
appendix A. Any deficiencies which the organizational maintenance personnel are not authorized to
correct must be
reported as stipulated in TM 38-750.
4-14. Generator Receptacle Box Cable, Condulet, Cover and Receptacle Connectors
a. Removal.
(2) Disconnect the wires in the cable (6) from the generator.
NOTE
Tag the wires for identification if color-coded wires are not used.
(3) Remove the four screws that attach each of the covers (1 and 3) to the condulet, and remove the covers
and the gaskets from the condulet.
(4) Remove the two screws that secure the connectors (7 and 9) to the condulet, and lift the connectors from
the condulet.
NOTE
Some bath units come equipped with connectors fastened to the hinged lift covers. Removal is
the same with the exception of removing the screws from the covers in lieu of the condulet.
(5) Loosen the screws on the connectors and remove the wires from the connectors.
(6) Loosen the connector nut (5) and slide the cable (6) from the condulet.
b. Inspection. Inspect for frayed and excessively worn cable; cracked or broken condulet; damaged or stripped
threads on the condulet; broken hinge springs and cover; and cracked or broken connectors.
c. Installation. Replace defective items with serviceable ones. Install serviceable ones by reversing the procedure
in a above, connecting the wires according to the wiring diagram shown in figure 4-4.