NOTES
1. Lubricate washer alternating current motor per steps below:
a.
Remove electrical power from laundry unit.
b.
Remove belt guard cover.
c.
Apply grease per Table 1 to grease fittings.
d.
Install belt guard cover.
2. Lubricate washer gear reducer per one of steps below:
a. Check level of lubricant (semiannually) per substeps below:
(1)
Remove electrical power from laundry unit.
(2)
Remove belt guard cover.
(3)
Remove level plug.
(4)
Remove fill plug.
(5)
Add lubricant per Table I until it flows out of level hole.
(6)
Install level plug.
(7)
Install fill plug.
(8)
Install belt guard cover.
b. Drain and refill lubricant (annually) per substeps below:
(1) Remove electrical power from laundry unit.
(2) Remove belt guard cover.
(3) Place container (to hold lubricant) under drain plug.
(4) Remove drain plug.
(5) Remove fill plug.
(6) Remove level plug.
(7) Install drain plug.
(8) Add lubricant per Table 1 until it flows out of level hole.
(9) Install level plug.
(10) Install fill plug.
(11) Install belt guard cover.
Card 9 of 12