6. Lubricate dryer trunnion ball bearings per steps below:
a. Remove electrical power from laundry unit.
NOTE
If grease cups have been turned down all the way, they
need to be removed and filled per Table 3 with lubricant.
b. Turn grease cups to the right one-quarter turn.
7. Lubricate dryer chain per steps below:
a.
Remove electrical power from laundry unit.
b.
Open oil lube cover.
c.
Apply a few drops of lubricant, per Table 3, in hole.
d.
Close oil lube cover.
8. Lubricate dryer gear reduction unit per one of steps below:
a. Check level of lubricant (quarterly) per substeps below:
(1)
Remove electrical power from laundry unit.
(2)
Remove level plug.
(3)
Remove fill plug.
(4)
Add lubricant per Table 3, until it flows out of level hole.
(5)
Install level plug.
(6)
Install fill plug.
b. Drain and refill lubricant (semiannually) per substeps below:
(1)
Remove electrical power from laundry unit.
(2)
Place container (to hold lubricant) under drain plug.
(3)
Remove drain plug.
(4)
Remove fill plug.
(5)
Remove level plug.
(6)
Install drain plug.
(7)
Add lubricant per Table 3, until it flows out of level hole.
(8)
Install level plug.
(9)
Install fill plug.
Card 11 of 12