TM 10-3510-208-12
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
16. WATER PUMP FAILS TO ROTATE
Step 1. Check for a broken or cracked motor, damaged shaft threads, and bent shaft.
Replace motor, if defective. Remove the motor using illustrations and instructions listed in figures 4-11 and
4-12.
Step 2. Check for a clogged impeller,
Clean the impeller.
17. WASHER-EXTRACTOR BASKET WILL NOT ROTATE
Step 1. Check for locked brake assembly.
Correct pressure or replace possible defective air cylinder (fig. 4-95).
Step 2. Check for a broken or cracked motor, damaged shaft threads, and bent shaft.
Figure 4-13. Washer motor, drive belts, and sheave, removal and installation (Eidal Model ELT9T).
4-22