TM 10-3510-209-10
2-9. OPERATING PROCEDURES. (CONT)
e.
Shutdown Procedures.
NOTE
The laundry unit may begin to be shut down while the last load of wash is being
dried.
(1)
Make certain that all washer control panel switches are in the OFF position.
(2)
Turn off air compressor circuit breaker (3, FIG. 2-7) at the power distribution panel.
(3)
Turn water temperature control (6, FIG. 2-4) to O0F (-180C). Allow the water heater to
operate for 2 minutes so that the blower may purge vaporized fuel from the burner. Turn
ON/OFF switch (7) to the OFF position and close fuel shutoff valve (9).
(4)
Turn off start switch (1, FIG. 2-6) on the water pump.
(5)
Turn dryer temperature control (9, FIG. 2-2) to O0F (-180C). Allow the dryer to operate for 2
minutes so that the blower may purge vaporized fuel from the burner. Press the stop button
(5) and close fuel shutoff valve (12).
(6)
Open the dryer door and allow the dryer to cool for 3 to 5 minutes.
(7)
Set all circuit breakers on the power distribution box to off (FIG. 2-7).
(8)
Refer to TM 5-6115-585-12 and shut down the generator set.
2-10. PREPARATION FOR MOVEMENT.
a.
Perform shutdown operations. (Refer to para 2-9e.)
b.
Remove tarp, two struts, and workstand support brackets from the hose basket and set aside.
WARNING
Use extreme care to avoid spilling fuel. Fuel is highly flammable and may explode
if exposed to heat or spark. Clean up spills as soon as possible. Failure to observe
this warning may result in death or serious injury to personnel.
c.
Disconnect and drain back into fuel source four fuel lines going to the dryer and water heater.
Store fuel lines in hose basket.
d.
Remove the drum fill adapters from the fuel source and store in hose baskets.