TM 55-1945-205-24-4
2-37.1. WATER MANIFOLD ASSEMBLY (CONT)
DISASSEMBLY (CONT)
a.
Loosen nut (20) and lock washer (21) from crank (31).
b.
Remove lock nut (22). Slide air actuated ball valve assembly (16 or 1), two teflon bushings (24) and spacer
(25) off of bolt (23).
c.
Loosen nuts (26 and 18) and remove anchor bracket (27) from pipe (3 or 2).
d.
Remove pipe (3 or 2) from air actuated ball valve assembly (1 or 16).
REPAIR
Replace any broken or defective fittings or parts.
ASSEMBLY
NOTE
Use thread sealing compound on all connections to prevent leaks.
1.
To assemble pipe (2 or 3) onto the air actuated ball valve assembly (1 or 16), perform the following steps:
a.
Install pipe (2 or 3) into air actuated ball valve assembly (1 or 16).
b.
Install anchor bracket (27) on pipe (2 or 3). Do not tighten bolts (23 and 17) or nuts (26 and 18) until
adjustment procedures are complete.
c.
Place air actuated ball valve assembly (16 or 1) with two teflon bushings (24) and spacer (25) onto bolt (23)
and install lock nut (22). Nut (22) tightened in next step.
d.
Tighten nut (20) and lock washer (21) to secure crank (31). Tighten nut (22).
e.
Perform adjustment procedures then tighten bolts (23 and 17) and nuts (26 and 18).
2-134.4 Change 1