TM 55-1945-205-24-4
2-37.1. WATER MANIFOLD ASSEMBLY (CONT)
ASSEMBLY (Cont)
2.
Install elbow (12), nipple (6), bushing (8B) and coupling (11) onto steel pipe (3).
3.
Install nipple (15) and tee (7) onto air actuated ball valve assembly (16).
4.
Install nipple (5), bushing (8A), street elbow (9) and coupling (10A) onto tee (7).
5.
Install nipple (4) onto tee (7) and place one clamp assembly (29) on nipple (4). Nuts (28) tightened during
installation.
6.
Install air actuated ball valve assembly (1) onto nipple (4). Place another clamp assembly (29) on steel pipe (2).
Install bushing (8) and coupling (10) onto pipe (2).
INSTALLATION
NOTE
If manifold assembly has been disassembled or repaired the assembly may require
adjustment to mate with water heater attachment points. Make adjustments by
turning fittings or pipes as required.
1.
Connect coupling (11) to fitting on top of water heater. Make alignment adjustments if necessary.
2.
Install two upper clamps (35) onto clamp assemblies (29). Install two lower clamps (36), four lock washers (38)
and four nuts (37) onto clamp assemblies. When manifold is in desired position, tighten four nuts (28) and four nuts (37).
3.
Connect short water hose to water heater tee then connect opposite end to manifold assembly.
4.
Connect washer water intake hose to manifold.
5.
Connect the two air lines to hose fittings (13) as marked during removal.
2-134.6 Change 1