TM 10-3510-220-10
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Remove two bolts (5) and remove bracket assembly (4).
Remove two bolts (3) and remove bracket assembly (2).
Remove water pump (1) and locate it no more than 10 feet (3m) from
the water source.
Install brackets (2) and (4) and tighten bolts (3) and (5) removed in step
(2).
Connect suction hose (9, figure 2-9) to suction inlet (10).
WARNING
Ensure that water hoses (7 and 9, figure 2-9) do not
touch or cross other water hoses, exhaust ducts, power
cables, or fuel lines.
Melting/damage can occur
causing leaking fuel and water or electrical hazards.
Death by electrocution, fire, or explosion could result.
Connect suction strainer (8) to the other end of suction hose (9).
Position the strainer in the water source above the stream bed. Make a
tripod from tree branches or saplings and hang the strainer from the
place where the branches are tied together, or position the strainer on
a bed of stones or gravel.
Connect water heater intake hose (7)
(12).
Connect the other end of the heater
inlet (6).
to water pump discharge outlet
intake hose (7) to water heater
2-37
2-7. SITE SELECTION, SET UP, AND ASSEMBLY. (CONT)
c. Set up water pump and hose assemly as follows: