TM 10-3510-220-10
2-7.
SITE SELECTION, SETUP, AND ASSEMBLY. (CONT)
(10) Be sure petcock valve (11) on water pump housing is closed. Clockwise
rotation closes valve.
(11) Be sure petcock valve (4) drain valve (5) and vent valve (15) on the
water heater are closed. Clockwise rotation closes valve.
(12) Be sure washer inlet hose (2) is connected to washer inlet (1) and to
water heater outlet (3).
(13) Be sure that hose (14) from water heater inlet (13) is connected.
(14) Be sure that drain hose (4, figure 2-10) is connected to extractor drain
connection (5) and washer drain connection (3).
WARNING
Be sure that drain hoses (1 and 7, figure 2-10) do not
touch or cross other water hoses, power cables,
exhaust ducts, or fuel lines.
Melting/damage can
occur causing leaking fuel and water or electrical
hazards. Death by electrocution, fire, or explosion
could result.
(15) Connect one 25-foot (7.6 m), l-1/2-inch-diameter drain hose (7) to pre-
extration bin drain (6) and route the hose to a drain field. Do not touch
or cross other water hoses, power cables, exhaust ducts, or fuel lines.
(16) Connect one 25-foot (7.6m), 2-1/2-inch-diameter drain hose (1) to
washer drain (2) and route the hose to a drain field. Do not touch or
cross other water hoses, power cables, exhaust ducts, or fuel lines.
d.
Set up electric power cables as follows:
WARNING
The laundry unit uses 208 V ac. All circuit breakers
on the electrical panel must be off prior to connecting
electrical power cables.
Failure to observe safety
precautions may result in death or serious injury.
(1) Open electrical panel door (5, figure 2-11) and turn off all circuit
breakers(6).
(2) Remove dust cap (1) on main power connection (2).
(3) Remove dust cap (4) from main power cable (3).
2-39