f. Drying Tumbler.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Set thermoswitch (15, figure 2-19) as follows:
(a) For cotton: 250°F (121ºC)
(b) For wool: 200°F (93°C)
(c) For battle dress uniform (BDUS): do not exceed 130°F (54°C)
Set electric timer (16) to approximately 10 minutes.
Adjust burner air intake (1) to approximately 1/2 inch (12.7 mm).
Close fuel shutoff valve (5).
Remove three thumb screws (11) on panel door (12) of dryer control
panel (8) and open panel door (12).
Press reset button (14) on safeWard control unit (13). Close and secure
panel door with three thumb screws (11).
Push START button (7) on dryer control panel (8).
Check fuel pressure gage (4) for an indication of approximately 100 psi
(690 kPa).
Open fuel shutoff valve (5) one full turn.
NOTE
The dryer burner is equipped with an ultraviolet (UV)
scanner and a flame safeguard control unit to purge
fumes or vapor from the combustion chamber prior to
ignition.
The control unit will also cause a safety
shutdown if the burner does not ignite within a preset
time.
If dryer warning light (10) lights and beeper (9) sounds on the front of
dryer control panel (8) perform the following:
(a)
(b)
(c)
(d)
(e)
Push STOP/RESET (6) on dryer control panel (8).
Loosen three thumb screws (11) on panel door (12) of dryer control
panel (8) and open panel door (12).
Wait for approximately 2 minutes after shutdown to allow for the
safeguard timer to reset and cool the electrical igniter.
Press and release reset button (14) on safeguard control unit (13).
Close panel door (12) on dryer control panel (8) and secure with
three thumbscrews(n).
Push START button (7) on dryer control panel (8).