TM 10-3510-220-10
f. Shutdown Procedures cont.
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
(m)
(n)
Connect garden hose to drain valve on bottom of water heater.
Open drain valve on bottom of water heater.
Open bleeder valve, (9, figure 2-4) on top of water heater until a steady stream flows from garden
hose.
NOTE
Wait until water has drained before proceeding to next step.
Remove nonmetallic hose (1, 2, 6 figure 2-10) from washer quick coupling half and from
water heater quick coupling half. Store in basket.
On backside of washer control panel locate airlines to ball valve of water heater, cycle solenoid
of vertical valve, then cycle horizontal valve three times to drain water.
After water has stopped draining from garden hose, close drain valve.
Disconnect garden hose from drain valve and store in basket.
Close bleeder valve on top of water heater.
Open drain cock on washer air tank and drain all water.
Close air tank drain cock.
(8)
Set all circuit breakers on the power distribution panel to off (figure 2-6).
(9)
Refer to TM 5-6115-585-12 and shutdown the generator set.
Change 2
2-68.1