TM 10-3510-220-24
2-34. WATER HEATER ASSEMBLY (CONT)
ADJUSTMENT (Cont)
1.
For adjustment of fuel pump,
refer to para. 2-39.
2.
3.
For adjustment of burner electrodes,
refer to para. 2-36.
Adjust operating temperature
control (4). Turn knob from 0
to 250 degrees and check pointer
calibration. Adjust position by
loosening setscrew and moving
knob to correct position.
Tighten setscrew.
REPAIR
1.
2.
3.
Remove and replace only those items necessary to make repair.
Repair of water heater assembly consists of replacing defective components and making needed
adjustments. Refer to individual water heater component paragraphs.
After replacing the defective components, ensure that the water heater is operating correctly
by making a visual inspection and performing an operating check. (Refer to TM 10-3510-220-
10.)
Perform follow-on installation.
Install tarp assembly (TM 10-3510-220-10).
2-105